Toggle navigation SEARCH FOR PROPERTY
Property Features
FEATURES & AMENITIES BUILDING ENTRANCE FRONT ELEVATION OF THE BUILDING WILL HAVE THE BEST OUTLOOK WITH THE USE OF HIGH QUALITY BUILDING MATERIALS. • PROJECT NAME WITH ADDRESS WILL BE INSCRIBED AT A STRATEGIC LOCATION AS ADVISED BY PROJECT ARCHITECT WITH EXCLUSIVE MATERIALS. • SECURED, DECORATIVE AND PRESTIGIOUS GATE WITH SPACIOUS ENTRANCE AND DRIVEWAY. • GUARD POST FOR CONTROLLING INCOMING AND OUTGOING PERSONS, VEHICLES AND GOODS. • COMFORTABLE INTERNAL DRIVEWAY. • EXCLUSIVE MAIN ENTRANCE AT GROUND LEVEL WITH RECEPTION AS PER DESIGN 1.2 RECEPTION, LOBBY & GROUND FLOOR MAIN LOBBY & RECEPTION AREA IN SECURED PREMISES WITH BEAUTIFUL CONCIERGE DESK. • RECEPTION AREA FLOOR WILL BE FINISHED WITH GOOD QUALITY TILES. • TILES WORK ON LIFT FACE. • INTERCOM FACILITIES IN RECEPTION AREA. • TILES IN LIFT LOBBY IN THE GROUND FLOOR. • GREEN PLANTATION IN SUITABLE LOCATION. LIFTS • NUMBERS : 02 (TWO) PASSENGER LIFTS. • BRAND : HYUNDAI/MAAN BANGLADESH/EQUIVALENT • CAPACITY : CAPABLE TO CARRY 08 (EIGHT) PERSONS. • SPEED : 1.6 METER/SEC. • DRIVE SYSTEM : AC/VVVF, VARIABLE VOLTAGE & VARIABLE FREQUENCY • INTERCOM : CAR, MACHINE ROOM, RECEPTION AND LIFT. • EMERGENCY ALARM PROVISION. LIFT, LOBBY AND STAIRCASE • SPACIOUS LIFT, LOBBY AND STAIRWAY IN EACH FLOOR WITH PROPER VENTILATION. • ALL LOBBIES FINISHED WITH (RAK/EQU) TILES WITH PROPER LIGHTING SYSTEM. • FIRE ALARM & FIRE EXTINGUISHER IN EACH FLOOR INCLUDING GROUND FLOOR. • COMBINATION OF MS AND OTHER MATERIAL RAIL IN STAIRCASE ( AS PER ARCHITECTURAL DESIGN) APARTMENT LAYOUT THE TOTAL LAYOUT HAS BEING BE THOUGHTFULLY ARRANGED TO MAXIMIZE ADVANTAGES, ESPECIALLY IN RELATION TO THE DAY LIGHT FROM ALL SIDES AND CROSS - VENTILATION THROUGHOUT. • SPREADING THE LAYOUT FROM END TO END. • THE DESIGN OF THE APARTMENT WILL EMPHASIZE IN PRIVACY. • ALL ROOMS CAN TAKE ADVANTAGE OF BOTH THE WINTER SUNLIGHT AND COOL SUMMER BREEZE. PAGE 2 GENERATOR ONE STANDBY GENERATOR WITH CANOPY: • ENGINE : PERKINS /CUMMINS/PRAMAC OR EQUIVALENT (WITH CANOPY) • ORIGIN : UK/ ITALY • STARTING SYSTEM: AUTO STARTER. • RATING : AS PER CALCULATED REQUIREMENT • WARRANTY: AS PER MANUFACTURER • CAPACITY TO COVER LIFT, WATER PUMPS, COMMON LIGHTS, TWO LIGHTS AND TWO FANS WITH ONE POWER POINT IN EACH APARTMENT. WATER SUPPLY TWO UNITS (ONE STANDBY) FOR BETTER SERVICES. • 02 (TWO) RFL/GAZI/ EQUIVALENT. ROOF TOP PROTECTIVE PARAPET WALL OF STANDARD HEIGHT. • RCC OVERHEAD TANK FOR 02(TWO) DAYS WATER STORAGE. • PAVEMENT TILES ON ROOF TOP. • PROVISION FOR ROOF TOP GARDEN. • LIFT MACHINE ROOM. • WATER OUTLET PROVISION FOR GARDENING. • ONE COMMON COMMUNITY HALL WITH BATHROOM & KITCHEN. • SOLAR PANEL AS PER REQUIREMENTS. INTERCOM IMPORTED BRAND -PANASONIC/EQUIVALENT. (VIETNAM/MALAYSIA) SUB- STATION A SUB-STATION WILL BE INSTALLED ARRANGED ON THE GROUND FLOOR. BRAND – TRANSPAC/ RADIANT POWER/ PATEL CO /ENERGYPAC/ EQUIVALENT. MAIN ENTRANCE DOOR: • SOLID WOODEN DECORATIVE MAIN ENTRANCE DOOR & FRAME (TEAK). • IMPORTED DOOR LOCK. • DOOR CHAIN & CHECK VIEWER. • SECURITY LOCK. • APARTMENT NUMBER PLATE. INTERNAL DOORS: • ALL INTERNAL DOORFRAMES WILL BE MAHOGANY WOOD. (EXCEPT SERVANT TOILET/STORE) • ALL INTERNAL DOORS OF STRONG & DURABLE VENEER FLUSH SINGLE DOOR SHUTTER WITH FRENCH POLISH. (PARTEX/AMBER) • ALL BATHROOMS DOORS WILL BE GOOD QUALITY UPVC SHUTTER. • MORTISE LOCK IN ALL DOORS. • ALL VERANDA DOORS WITH OUTER-SIDE WATER PROOF WOODEN DOORS. (GAMARY WOOD) WINDOWS • SLIDING ALUMINIUM WINDOWS AS PER ARCHITECTURAL DESIGN OF THE BUILDING. PAGE 3 • 5MM THICKNESS GLASS WITH MOHAIR LINING. • RAIN WATER BARRIER INSIDE OF ALUMINIUM SECTIONS. • SAFETY GRILLS IN ALL WINDOWS. • FRONT VERANDA RAILING WITH MS (AS PER ARCHITECTURAL DESIGN) • FLY PROOF NET IN ALL WINDOWS. WALLS • GOOD QUALITY 1ST CLASS BRICKS. • SMOOTH FINISH WALLS. GENERAL FLOORS & VERANDAH • RAK/DBL/EQUIVALENT FLOOR TILES (24’ X 24’) WITH 4” SKIRTING. • FLOOR TILES (24”X24”) IN ALL VERANDAHS. (RAK/DBL/EQUIVALENT) • FLOOR TILES IN ALL VERANDAHS. PAINTING & POLISHING • PLASTIC PAINT IN ALL INTERNAL WALLS AND CEILING IN SOFT COLORS (BERGER/ELITE/ASIAN/EQU.) • FRENCH POLISHED DOORFRAMES & SHUTTERS. • EXTERIOR WALL WILL BE WEATHER COAT PAINT (BERGER/ELITE/EQU.) ELECTRICAL FITTING & FIXTURES • ALL ELECTRICAL WIRINGS, PHONE LINES, GAS & WATER LINES ETC. WILL BE CONNECTED. (BRB CABLE/BBS/PARTEX/ PARADISE/EQU.) • MK TYPE ELECTRICAL SWITCHES, PLUG POINTS AND OTHER FITTINGS. (ENERGYPAC/EQU) • PROVISION FOR FANCY LIGHT FIXTURES IN ALL ROOMS. • ELECTRICAL DISTRIBUTION BOX WITH MAIN SWITCH AND CIRCUIT BREAKERS FOR ALL LINES. (ABB/EQU) • PROVISION FOR AIR-CONDITIONERS IN MASTER BED, CHILD BED AND LIVING AREA. • ONE INTERNET POINT IN EACH APARTMENT. • CONCEALED WIRING WITH PLUG POINTS FOR REFRIGERATOR AND FREEZER IN THE DINING HALL OR KITCHEN AREA. • ALL POWER OUTLETS WITH EARTHLING CONNECTION. • GEYSER POINT AT ALL BATH AND KITCHEN (EXCEPT SERVANT BATH). • ONE THREE PIN POINT AT ALL BED ROOM, LIVING, DINING AND KITCHEN. • ONE TWO PIN POINT AT ALL MASTER BATH ROOM. • PROVISION FOR KITCHEN HOOD POINT AT KITCHEN. • ALL CIRCUIT BREAKER WILL BE ABB. • THREE LIGHT POINTS IN ALL ROOMS OF THE APARTMENT. BATH ROOMS MASTER BATH: • FLOOR TILES MATCHING WITH CERAMIC TILES UP TO CEILING (RAK/DBL/ EQUIVALENT). (12”*20”) • SHOWER ENCLOSURE. (DEVELOPER STANDARD) • COMBI CLOSET WITH CABINET BASIN (RAK-ORIENT-MIRA) • SHOWER MIXER & BASIN MIXER. (NAZMA/SATTAR/ EQUIVALENT) • BASIN COUNTER TOP WILL BE FINISHED WITH MARBLE PAGE 4 • GOOD QUALITY SOAP CASE, TOWEL RAIL, PAPER HOLDER, PUSH SHOWER & MIROR. • CONCEALED HOT AND COLD WATER LINES. • EXHAUSTS FAN PROVIDED. CHILDREN BATH • COMMODE PEDESTAL BASIN (RAK-KARLA). • SHOWER MIXER & BASIN MIXER.(NAZMAN/SATTAR/EQU). • GOOD QUALITY SOAP CASE, TOWEL RAIL, PAPER HOLDER, PUSH SHOWER & MIROR. • FLOOR TILES (12”*12”) MATCHING WITH WALL (RAK/DBL/ EQU). • WALL TILES UP TO CEILING 12”*20” (RAK/DBL/ EQU). • CONCEALED HOT AND COLD WATER LINES. • EXHAUSTS FAN PROVIDED. COMMON BATH • COMMODE WITH PEDESTAL BASIN (RAK- KARLA/ EQU) • BASIN MIXER.(NAZMAN/SATTAR/EQU). • CONCEALED STOP COCK , BIB COCK & HEAD SHOWER (SATTAR/NAZMA/EQU) • GOOD QUALITY SOAP CASE, TOWEL RAIL, PAPER HOLDER, PUSH SHOWER & MIROR. • FLOOR TILES (12”*12”) MATCHING WITH WALL (RAK/DBL/ EQU). • WALL TILES UP TO CEILING 12”*20” (RAK/DBL/ EQU). • CONCEALED HOT & COLD WATER LINE. • EXHAUSTS FAN PROVIDED. SERVANT BATH • WALL TILES (8”*12”) UP TO 7’-0” HEIGHTS AKIJ/GREAT WALL/CBC/EQU. • FLOOR TILES (12”*12”) AKIJ/GREAT WALL/CBC/EQU. • LONG PAN WITH LOW DOWN (BISF/RAK/EQU) • LOCAL FITTINGS, CONCEALED STOP COCK, BIB COCK & HEAD SHOWER. • EXHAUSTS FAN PROVISION. • PLASTIC DOOR • SOAP CASE & TOWEL RAIL. 2.8. KITCHENS • GRANITE WORKTOP (2’-0”X1’-0”) (RUBY RED/BLACK) • PROVISION FOR ONE DOUBLE BURNER GAS OUTLET. • FLOOR TILES (12”*12”) MATCHING WITH WALL (RAK/DBL/ EQU). • WALL TILES UP TO 7’-0” HEIGHT 12”*20” (RAK/DBL/ EQU). • ONE STAINLESS STEEL SINGLE BOWL SINGLE TRAY SINK WITH MIXER.(SATTAR/NAZMA/SHARIF/EQU) • EXHAUST FAN AT SUITABLE LOCATION. • CONCEALED HOT AND COLD WATER LINES. • PROVISION FOR MICROWAVE OVEN CONNECTION. 3.0 MISCELLANEOUS FEATURES • CONCEALED TELEPHONE CONNECTION POINTS IN MASTER BEDROOM AND LIVING ROOM. • CONCEALED TV CABLE LINE IN MASTER BEDROOM AND LIVING ROOM. PAGE 5 4.0 GENERAL AMENITIES OF THE COMPLEX • 3-PHASE MAIN ELECTRICITY SUPPLY APPROX 220 V/440 V FROM DESA SOURCE WITH SEPARATE MAIN CABLE/DISTRIBUTION BOARD. • WATER SUPPLY CONNECTION FROM WASA SUFFICIENT AS PER TOTAL CALCULATED CONSUMPTION. • UNDERGROUND WATER RESERVOIR WITH MAIN LIFTING PUMP AND STANDBY PUMP. • SEWERAGE SYSTEM PLANNED FOR LONG TERM REQUIREMENT. • GAS PIPELINE CONNECTION FORM AVAILABLE SOURCE OF CONCERNED AUTHORITY (TITAS GAS TRANSMISSION & DISTRIBUTION COMPANY LTD) AS PER TOTAL CALCULATED CONSUMPTION, ADEQUATE SAFETY MEASURES INCORPORATED. • TERMITE PROTECTION TREATMENT IN GROUND FLOOR. • SEPARATE BILLING SYSTEM FOR ELECTRICITY & GAS OF EACH APARTMENT ACCORDING TO INDIVIDUAL METER. WATER SUPPLY AND SEWERAGE WILL HAVE COMMON METER CONNECTION FOR THE PROJECT. • ONE STANDBY GENERATOR AND TRANSFORMER OF ADEQUATE CAPACITY. • EMERGENCY ELECTRIC SUPPLY THROUGH GENERATOR FOR COMMON SPACE, STAIR AND OPERATING LIFT. • SOFT COLOUR WEATHER COAT PAINT (BERGER, ELITE OR EQUIVALENT) ON OUTSIDE WALLS. • FIRE EXTINGUISHER IN ALL FLOORS. 5.0 STRUCTURAL & ENGINEERING FEATURE: • BUILDING WILL BE PLANNED AND DESIGNED BY PROFESSIONAL ARCHITECTS AND STRUCTURAL DESIGN ENGINEERS. • FOR ALL SERVICE CONNECTIONS AND DISPOSALS. (SEWERAGE, SOLID WASTE, ETC.) BRITISH/AMERICAN/BNBC BUILDING CODES WILL BE FOLLOWED. • STRUCTURAL DESIGN PARAMETERS WILL BE BASED OF AMERICAN CONCRETE INSTITUTE (ACI) AND AMERICAN STANDARDS OF TESTING MATERIALS (ASTM) AND BNBC CODES. • SUB-SOIL INVESTIGATION AND SOIL COMPOSITION WILL BE ANALYZED FROM LABORATORY. • BUILDING WILL BE COMPRISED OF REINFORCED CEMENT CONCRETE (R.C.C) FOUNDATION, COLUMN, BEAM AND SLAB CONSIDERING SYSTEMATIC AND WIND EFFECT WITH MODERN DESIGN CONCEPT. • COMPREHENSIVE CHECKING AND TESTING OF ALL STEEL REINFORCEMENT WILL BE CONDUCTED BY PROFESSIONAL DESIGN AND SUPERVISING ENGINEERS. • ALL STRUCTURAL MATERIALS INCLUDING STEEL (60 GRADE DEFORMED / TORE STEEL BAR), CEMENT (SCAN, CEMEX, HOLCIM, ETC.), BRICKS (1ST CLASS COAL BURN), SYLHET SAND, ETC, WILL BE OF HIGHEST AVAILABLE STANDARD. • FOR CONCRETE WORKS TO GIVE CRUSHING STRENGTHS OF 2500 PSI TO 3500 PSI (CYL. TEST) AT 28 DAYS DEPENDING ON CONCRETE RATIO & DESIGN.
Similar Properties