ELECTRICAL FITTING & FIXTURES
• ALL ELECTRICAL WIRINGS, PHONE LINES, GAS & WATER LINES ETC. WILL BE CONNECTED. (BRB CABLE/BBS/PARTEX/ PARADISE/EQU.)
• MK TYPE ELECTRICAL SWITCHES, PLUG POINTS AND OTHER FITTINGS. (ENERGYPAC/EQU)
• PROVISION FOR FANCY LIGHT FIXTURES IN ALL ROOMS.
• ELECTRICAL DISTRIBUTION BOX WITH MAIN SWITCH AND CIRCUIT BREAKERS FOR ALL LINES. (ABB/EQU)
• PROVISION FOR AIR-CONDITIONERS IN MASTER BED, CHILD BED AND LIVING AREA.
• ONE INTERNET POINT IN EACH APARTMENT.
• CONCEALED WIRING WITH PLUG POINTS FOR REFRIGERATOR AND FREEZER IN THE DINING HALL OR KITCHEN AREA.
• ALL POWER OUTLETS WITH EARTHLING CONNECTION.
• GEYSER POINT AT ALL BATH AND KITCHEN (EXCEPT SERVANT BATH).
• ONE THREE PIN POINT AT ALL BED ROOM, LIVING, DINING AND KITCHEN.
• ONE TWO PIN POINT AT ALL MASTER BATH ROOM.
• PROVISION FOR KITCHEN HOOD POINT AT KITCHEN.
• ALL CIRCUIT BREAKER WILL BE ABB.
• THREE LIGHT POINTS IN ALL ROOMS OF THE APARTMENT.
BATH ROOMS
MASTER BATH:
• FLOOR TILES MATCHING WITH CERAMIC TILES UP TO CEILING (RAK/DBL/ EQUIVALENT). (12”*20”)
• SHOWER ENCLOSURE. (DEVELOPER STANDARD)
• COMBI CLOSET WITH CABINET BASIN (RAK-ORIENT-MIRA)
• SHOWER MIXER & BASIN MIXER. (NAZMA/SATTAR/ EQUIVALENT)
• BASIN COUNTER TOP WILL BE FINISHED WITH MARBLE PAGE 4
• GOOD QUALITY SOAP CASE, TOWEL RAIL, PAPER HOLDER, PUSH SHOWER & MIROR.
• CONCEALED HOT AND COLD WATER LINES.
• EXHAUSTS FAN PROVIDED.
CHILDREN BATH
• COMMODE PEDESTAL BASIN (RAK-KARLA).
• SHOWER MIXER & BASIN MIXER.(NAZMAN/SATTAR/EQU).
• GOOD QUALITY SOAP CASE, TOWEL RAIL, PAPER HOLDER, PUSH SHOWER & MIROR.
• FLOOR TILES (12”*12”) MATCHING WITH WALL (RAK/DBL/ EQU).
• WALL TILES UP TO CEILING 12”*20” (RAK/DBL/ EQU).
• CONCEALED HOT AND COLD WATER LINES.
• EXHAUSTS FAN PROVIDED.
COMMON BATH
• COMMODE WITH PEDESTAL BASIN (RAK- KARLA/ EQU)
• BASIN MIXER.(NAZMAN/SATTAR/EQU).
• CONCEALED STOP COCK , BIB COCK & HEAD SHOWER (SATTAR/NAZMA/EQU)
• GOOD QUALITY SOAP CASE, TOWEL RAIL, PAPER HOLDER, PUSH SHOWER & MIROR.
• FLOOR TILES (12”*12”) MATCHING WITH WALL (RAK/DBL/ EQU).
• WALL TILES UP TO CEILING 12”*20” (RAK/DBL/ EQU).
• CONCEALED HOT & COLD WATER LINE.
• EXHAUSTS FAN PROVIDED.
SERVANT BATH
• WALL TILES (8”*12”) UP TO 7’-0” HEIGHTS AKIJ/GREAT WALL/CBC/EQU.
• FLOOR TILES (12”*12”) AKIJ/GREAT WALL/CBC/EQU.
• LONG PAN WITH LOW DOWN (BISF/RAK/EQU)
• LOCAL FITTINGS, CONCEALED STOP COCK, BIB COCK & HEAD SHOWER.
• EXHAUSTS FAN PROVISION.
• PLASTIC DOOR
• SOAP CASE & TOWEL RAIL. 2.8.
KITCHENS
• GRANITE WORKTOP (2’-0”X1’-0”) (RUBY RED/BLACK)
• PROVISION FOR ONE DOUBLE BURNER GAS OUTLET.
• FLOOR TILES (12”*12”) MATCHING WITH WALL (RAK/DBL/ EQU).
• WALL TILES UP TO 7’-0” HEIGHT 12”*20” (RAK/DBL/ EQU).
• ONE STAINLESS STEEL SINGLE BOWL SINGLE TRAY SINK WITH MIXER.(SATTAR/NAZMA/SHARIF/EQU)
• EXHAUST FAN AT SUITABLE LOCATION.
• CONCEALED HOT AND COLD WATER LINES.
• PROVISION FOR MICROWAVE OVEN CONNECTION. 3.0
MISCELLANEOUS FEATURES
• CONCEALED TELEPHONE CONNECTION POINTS IN MASTER BEDROOM AND LIVING ROOM.
• CONCEALED TV CABLE LINE IN MASTER BEDROOM AND LIVING ROOM. PAGE 5 4.0
GENERAL AMENITIES OF THE COMPLEX
• 3-PHASE MAIN ELECTRICITY SUPPLY APPROX 220 V/440 V FROM DESA SOURCE WITH SEPARATE MAIN CABLE/DISTRIBUTION BOARD.
• WATER SUPPLY CONNECTION FROM WASA SUFFICIENT AS PER TOTAL CALCULATED CONSUMPTION.
• UNDERGROUND WATER RESERVOIR WITH MAIN LIFTING PUMP AND STANDBY PUMP.
• SEWERAGE SYSTEM PLANNED FOR LONG TERM REQUIREMENT.
• GAS PIPELINE CONNECTION FORM AVAILABLE SOURCE OF CONCERNED AUTHORITY (TITAS GAS TRANSMISSION & DISTRIBUTION COMPANY LTD) AS PER TOTAL CALCULATED CONSUMPTION, ADEQUATE SAFETY MEASURES INCORPORATED.
• TERMITE PROTECTION TREATMENT IN GROUND FLOOR.
• SEPARATE BILLING SYSTEM FOR ELECTRICITY & GAS OF EACH APARTMENT ACCORDING TO INDIVIDUAL METER. WATER SUPPLY AND SEWERAGE WILL HAVE COMMON METER CONNECTION FOR THE PROJECT.
• ONE STANDBY GENERATOR AND TRANSFORMER OF ADEQUATE CAPACITY.
• EMERGENCY ELECTRIC SUPPLY THROUGH GENERATOR FOR COMMON SPACE, STAIR AND OPERATING LIFT.
• SOFT COLOUR WEATHER COAT PAINT (BERGER, ELITE OR EQUIVALENT) ON OUTSIDE WALLS.
• FIRE EXTINGUISHER IN ALL FLOORS. 5.0
STRUCTURAL & ENGINEERING FEATURE:
• BUILDING WILL BE PLANNED AND DESIGNED BY PROFESSIONAL ARCHITECTS AND STRUCTURAL DESIGN ENGINEERS.
• FOR ALL SERVICE CONNECTIONS AND DISPOSALS. (SEWERAGE, SOLID WASTE, ETC.) BRITISH/AMERICAN/BNBC BUILDING CODES WILL BE FOLLOWED.
• STRUCTURAL DESIGN PARAMETERS WILL BE BASED OF AMERICAN CONCRETE INSTITUTE (ACI) AND AMERICAN STANDARDS OF TESTING MATERIALS (ASTM) AND BNBC CODES.
• SUB-SOIL INVESTIGATION AND SOIL COMPOSITION WILL BE ANALYZED FROM LABORATORY.
• BUILDING WILL BE COMPRISED OF REINFORCED CEMENT CONCRETE (R.C.C) FOUNDATION, COLUMN, BEAM AND SLAB CONSIDERING SYSTEMATIC AND WIND EFFECT WITH MODERN DESIGN CONCEPT.
• COMPREHENSIVE CHECKING AND TESTING OF ALL STEEL REINFORCEMENT WILL BE CONDUCTED BY PROFESSIONAL DESIGN AND SUPERVISING ENGINEERS.
• ALL STRUCTURAL MATERIALS INCLUDING STEEL (60 GRADE DEFORMED / TORE STEEL BAR), CEMENT (SCAN, CEMEX, HOLCIM, ETC.), BRICKS (1ST CLASS COAL BURN), SYLHET SAND, ETC, WILL BE OF HIGHEST AVAILABLE STANDARD.
• FOR CONCRETE WORKS TO GIVE CRUSHING STRENGTHS OF 2500 PSI TO 3500 PSI (CYL. TEST) AT 28 DAYS DEPE